CALL US

+86 17838360708

new development of an annular gap mortar for mechanized

new development of an annular gap mortar for mechanized

New Development of an Annular Gap Mortar for mechanized ...

Mar 01, 2016  New Development of an Annular Gap Mortar for mechanizedTunnelling. Lifting forces act on the segment rings once they vacate the shield tail during shield drives involving segmental lining and annual gap mortar grouting. These can lead to pronounced misalignments of neighbouring rings and damage to the annular

get price

New Development of a Two-Component Annular Gap Mortar ...

Apr 01, 2016  A two-component mortar can be applied to avoid this damage, which reaches the necessary stiffness to support the segments once the components have been mixed in the annular gap. This report deals with the targeted new development and optimization of the mortar. An explicit set of requirements is defined and it is explained how aggregate is used ...

get price

Strength Development of Two-Component Grouts for Annular ...

Mar 01, 2018  Strength Development of Two-Component Grouts for Annular Gap Grouting. In mechanized tunnelling an early and safe bedding of the last inserted segment rings is a constructive necessity. This can purposefully be achieved by using a two-component mortar as grouting material whose composition is adapted for the geological and structural circumstances.

get price

New test stand for annular gap mortar STUVA e.V.

Jul 28, 2016  In recent years, the development of annular gap mortars - in particular through special products such as multi-component mortar - has become increasingly complex. Because now many substitutes and additives are used, which were previously reserved for high-quality construction concretes: Fly ashes and minerals,

get price

New Test Stand for annular Gap Mortars - tunnel

Jul 01, 2016  Example of Application: Water-permeable annular Gap Mortar. At present, a water-permeable annular gap mortar is being developed using the new test unit with the financial support of the German Federal Ministry for Economic Affairs and Energy (BMWi).

get price

New test stand for annular gap mortar - Tunnelling ...

New test stand for annular gap mortar Effective component optimization. A correctly executed annular gap compression in the tubbing tunnel is a basic prerequisite for a high quality tunnel construction. But it also provides a decisive contribution to a high propulsive power in mechanical propulsion.

get price

New Test Stand for annular Gap Mortars - tunnel

Example of Application: Water-permeable annular Gap Mortar. At present, a water-permeable annular gap mortar is being developed using the new test unit with the financial support of the German Federal Ministry for Economic Affairs and Energy

get price

New test stand for annular gap mortar STUVA e.V.

Jul 28, 2016  In recent years, the development of annular gap mortars - in particular through special products such as multi-component mortar - has become increasingly complex. Because now many substitutes and additives are used, which were previously reserved for high-quality construction concretes: Fly ashes and minerals,

get price

(PDF) Grouting of the annular gap in shield tunneling – an ...

In the mechanized excavation of tunnels with Tunnel Boring Machines (TBM), the filling of the annular gap, about 6 to 37 cm [41] but with typical values ranging between 13 and 20 cm [44, 2] is ...

get price

Shotcrete for Underground Support XIII

Jul 17, 2020  New Development of an annular gap mortar for mechanized tunnelling Matthias Hausmann, FH Münster, IuB, Germany 09:30 - 10:00 Structural retrofitting of rescue tunnels in single shell shotcrete construction – requirements and experiences Daniel Eickmeier, Federal Highway Research Institute (BASt), Germany

get price

Influencing parameters of the grout mix on the properties ...

In mechanized tunneling the annular gap between the segmental lining and the surrounding soil caused by tunnel driving, must be backfilled almost instantaneously with an adequate grouting mortar.

get price

Influencing parameters of the grout mix on the properties ...

In mechanized tunneling with segment lining the annular gap between segment lining and soil, caused by tunnel driving, must be backfilled instantaneously with an adequate grouting mortar, to avoid bulking of the surrounding soil, to embed the tunnel lining and to minimize settlements of the ground surface.

get price

Solidification of Two-Component Grouts by the Use of ...

Nov 08, 2019  Abstract. In mechanized shield tunneling, the annular gap between the tunnel structure and the surrounding soil needs to be filled with an adequate grouting mortar to ensure a rapid and safe bedding of the segment rings and to minimize settlements on the surface above the tunnel lining.

get price

Grouting mortar for annular injection

Grouting mortar for annular injection Olga Lyapidevskaya1,* 1 Moscow State University of Civil Engineering, Yaroslavskoe shosse, 26, Moscow, 129337, Russia Abstract. In

get price

Material technology developments in shield tunnelling ...

Jun 01, 2010  The development of segments made of high‐strength concrete does indeed enable higher load bearing capacities, but there are applications under very high overburden and related pressure where this alone is not sufficient. For such cases, a compressible mortar has been developed for the annular gap filling.

get price

Mechanized Tunnelling for two new Metro Lines in Rome - tunnel

Before mechanized tunnelling starts, the annular gap between ring segment and previously produced tunnel can be filled, sealing the tunnel construction towards the shaft. For a save entering into the target shaft 5/4 of Line C, a connecting ring with an activatable target seal and pressure-tight flanged cover plate was the solution manufactured ...

get price

Fachbereich Bauingenieurwesen - Publikationen - FH Münster

Veröffentlichungen. Hier finden Sie Artikel in Fachzeitschriften und Beiträge in Fachbüchern. "Reibungswinkel und Kohäsion von RSS-Flüssigboden nach dynamischer Belastung", Bautechnik 97 (2020), Heft 9, S. 637-646. "Minimalinvasive Sanierungsverfahren", Beton- und Stahlbetonbau 115 (2020), Heft 7, S. 532-541.

get price

Cementitious Composites with High Compaction Potential ...

In the context of mechanized tunneling, one method to increase the damage tolerance of tunnel linings in such conditions is the integration of a compressible two-component grout for the annular gap between the segmental linings and the deformable ground.

get price

Materials Free Full-Text Cementitious Composites with ...

There is an increasing need for the development of novel technologies for tunnel construction in difficult geological conditions to protect segmental linings from unexpected large deformations. In the context of mechanized tunneling, one method to increase the damage tolerance of tunnel linings in such conditions is the integration of a compressible two-component grout for the annular gap ...

get price

Articles de revues : « United States. Army. Maine Heavy ...

On June 2, 1862, William A. Hammond, Surgeon General of the United States Army, announced the intention of his office to collect material for the publication of a “Medical and Surgical History of the War of the Rebellion (1861–1865)” (1), usually called the Civil War of the United States of America, or the War Between the Union (the North; the Federal Government) and the Confederacy of ...

get price

SFB 837 - Ruhr-University Bochum

Overview. Within the development of innovative multi-component annular gap mortars, in subproject B3, in addition to the alkaline activation of slag-containing binder systems (Geopolymers), a rapid solidification on the physical level due to the addition of superabsorbent polymers (SAP) to a typical mortar could be achieved.

get price

SFB 837 - Ruhr-University Bochum

In order to ensure a sufficient stiffness development also under these circumstances, a two-component mortar had been investigated in the second phase of the project. The mortar mixture contains superabsorbent polymers (SAPs), which promote a rapid gelation process of the mortar within the annular gap.

get price

Cementitious Composites with High Compaction Potential ...

In the context of mechanized tunneling, one method to increase the damage tolerance of tunnel linings in such conditions is the integration of a compressible two-component grout for the annular gap between the segmental linings and the deformable ground.

get price

Influencing parameters of the grout mix on the properties ...

Abstract In mechanized tunneling with segment lining the annular gap between segment lining and soil, caused by tunnel driving, must be backfilled instantaneously with an adequate grouting mortar, to avoid bulking of the surrounding soil, to embed the tunnel lining and to minimize settlements of the ground surface. The decisive requirements for such annular gap grouts are on the one hand ...

get price

From advance exploration to real time steering of TBMs: A ...

Mar 01, 2018  Face support and annular gap grouting. The Earth Pressure Balanced (EPB) shield is worldwide predominantly applied for mechanized tunneling in coarse-grained soils. ... Unlike one-component mortar, the strength development is exclusively based on the hydration of the cement. The stabilizing mortar component A, consisting of cement, water ...

get price

Material technology developments in shield tunnelling ...

Jun 01, 2010  The development of segments made of high‐strength concrete does indeed enable higher load bearing capacities, but there are applications under very high overburden and related pressure where this alone is not sufficient. For such cases, a compressible mortar has been developed for the annular gap filling.

get price

Design Improvements of Segmental Linings Due to ...

Jan 01, 2017  For larger annular gap widths, no effects due to wall friction and arching effect may be expected [4]. 4. Design improvements An inhomogeneous distribution of pea gravel within the annular gap or uplifting forces due to low shear strength development of the used mortar – cement mixture affects not only the stress redistribution within ...

get price

A numerical study on backfilling of the tail void with two ...

In mechanized tunneling the annular gap between the segmental lining and the surrounding soil caused by tunnel driving must be backfilled instantaneously with an adequate mortar. The annular gap is caused due to the conical shape, overcut and design of the shield.

get price

Structural forces in segmental linings: process-oriented ...

May 01, 2021  Development of the elastic modulus and the permeability for the annular gap grouting mortar with time. Circles indicate experimental measurements of stiffness evolution according to (Schulte-Schrepping et al., 2018). Download : Download high-res image (220KB) Download : Download full-size image; Fig. 20.

get price

Mechanized Tunnelling for two new Metro Lines in Rome - tunnel

Before mechanized tunnelling starts, the annular gap between ring segment and previously produced tunnel can be filled, sealing the tunnel construction towards the shaft. For a save entering into the target shaft 5/4 of Line C, a connecting ring with an activatable target seal and pressure-tight flanged cover plate was the solution manufactured ...

get price

R. Breitenbücher - ITA Library

Dewatering and infiltration behaviour of annular gap grouts . Abstract: In mechanized tunnelling with segment linings, the annular gap between segment and soil must be filled instantaneously with an adequate grouting mortar. Thus, two contradictory requirements are demanded on annular gap grouts: On the one hand optimal flow properties lasting for several hours and sufficient stability against ...

get price

Analysis of the behavior of the two ... - ScienceDirect

Jul 01, 2021  In the mechanized excavation of tunnels with Tunnel Boring Machines (TBM), the filling of the annular gap, about 6 to 37 cm but with typical values ranging between 13 and 20 cm , is particularly important. The gap is created as the excavation progresses, between the TBM excavation profile and the extrados of the precast concrete segments (tunnel linings).

get price

Materials Free Full-Text Cementitious Composites with ...

There is an increasing need for the development of novel technologies for tunnel construction in difficult geological conditions to protect segmental linings from unexpected large deformations. In the context of mechanized tunneling, one method to increase the damage tolerance of tunnel linings in such conditions is the integration of a compressible two-component grout for the annular gap ...

get price

CORE

In mechanized tunneling the annular gap between the segmental lining and the surrounding soil caused by tunnel driving must be backfilled instantaneously with an adequate mortar. The annular gap is caused due to the conical shape, overcut and design of the shield.

get price